What can we do for you?

+49 7082 7916-0info[at]stratec.com

Immuno-
assay

Immuno-
assay

Immunoassays use the specific binding of antibodies to detect and quantify target molecules in biological samples.

Learn more

This field leverages the body's immune response to identify the presence of diseases, infections, or other health conditions by detecting antigens or antibodies in biological samples like blood, urine, or tissues. The fundamental concept behind immunodiagnostics is the interaction between antigens and antibodies. Antigens are molecules, which can bind to a specific antibody. The presence of antigens may trigger an immune response. Antibodies are proteins produced by the immune system that specifically bind to these antigens to neutralize or mark them for destruction by other immune cells.

fully automated chemiluminescence analyzer

LIAISON® XL

The success story of the LIAISON® series began in the early ’90s, when STRATEC and DiaSorin completed the initial development of a robust chemiluminescence analyzer – the LIAISON® Analyzer.

Following this success, STRATEC also developed the LIAISON® XL for DiaSorin, a fully automated chemiluminescence analyzer, that performs complete sample processing. The LIAISON® XL utilizes “Flash” chemiluminescence technology (CLIA) with a paramagnetic microparticle solid phase.

The fully automated chemiluminescence analyzer LIAISON® XL by STRATEC
LIAISON® XS

Alongside the LIAISON XL, which is designed for medium to high throughput, DiaSorin aimed to complement its successful product line with a fully automated, easy-to-use benchtop analyzer for the lower throughput segment. The LIAISON XS utilizes “flash” chemiluminescence technology (CLIA) and offers the same capabilities as Diasorin’s high-throughput analyzer, the LIAISON XL.

Challenge(s)

The Customer's Brief

LIAISON® XL

Due to the remarkable market success of the LIAISON® and the exceptional cooperation between STRATEC and DiaSorin, DiaSorin commissioned STRATEC to design a new analyzer that would meet the demands of a growing modern chemiluminescence market.

Higher throughput, speed, greater flexibility and improved usability were the predominant requirements for the project. 

STRATEC also had to pay particular attention to technologies specified or adopted by the customer. For example, the trapezoidal shape of the multi-cavity-cuvettes from the LIAISON was to be retained for a new single cavity design. At the same time the cuvette loading capacity was increased introducing cuvette bulk handling. The cuvette design and handling were a central challenge in the development. DiaSorin's existing cartridges, as well as the cover development according to the customer's design specification, also required special focus

LIAISON® XS

The central task in developing the LIAISON® XS was to equip the system with all the features of the LIAISON® XL, but in a more compact form. As STRATEC was already responsible for the LIAISON® XL, DiaSorin also entrusted STRATEC with the development of its smaller counterpart.

The technology was to remain unchanged without any loss of usability, and it was also required that the look and feel was preserved throughout the product line. STRATEC therefore had to rethink the LIAISON concept so that existing and proven modules, which have a certain degree of maturity, would also work for a benchtop system.
 

Our Solution

LIAISON® XL

In order to meet the above-mentioned requirements, STRATEC has developed groundbreaking innovations for this project.

LIAISON® XS

STRATEC was able to condense  the capabilities of the LIAISON® XL into a smaller, benchtop device by introducing some innovations:

  • Continuous Loading

      The instrument is designed for complete continuous loading including intermediate containers for DI water and wash buffer, allowing refilling without interrupting runs. Two waste containers with a switching valve are installed to enable emptying full containers during runs.

  • Incubation and wash steps

      While the majority of immunoanalyzers use circular arrangements in rings for incubation and wash steps, an oval incubator with a metal belt was developed that allowed an improved spatial arrangement. The channel for washing steps as well as the final measurement, is arranged linearly.

  • Process controls

      Reflecting the advances on electronics and software, different levels of process controls were introduced such as aspiration checks in the washer and aspirate/dispense checks for pipettor arms.

  • Instrument Design

      Outer covers were initiated by external designers of DiaSorin and implemented as large injection moulding pieces. 

      A fully closed cover design preventing access for the user during runs therefore fulfilling all safety requests. 

      While in the previous instrument, the PC and monitor were located next to the system, on the LIAISON® XL the PC itself is within the footprint and the instrument is operated by a touch monitor attached to the main cover. 

      Sample racks are kept on the instrument by a push-push mechanism and were designed for easy handling.

  • Pipetting

      STRATEC has developed a steel needle with Optical Liquid Verification (OLV) for pipetting the reagents. To avoid contamination during sample handling, STRATEC additionally developed a pipetting module with disposable tips. Both pipetting solutions proved to be groundbreaking innovations that had a significant impact on the general pipetting standard. They not only played a central role in this project, but also for STRATEC's success story. For years, STRATEC has relied on these proven technologies in other projects and also sells the derivatives of those pipettors as individual modules.

  • Cuvette design & handling

      Although DiaSorin had full control over the cuvette development, STRATEC provided support with its experience and was able to convince with the concept of individual cuvette processing, as this is more flexible and offers better user-friendliness for the end customer. STRATEC also developed a metal belt with holders for cuvettes as part of the incubator, which facilitates cuvette transportation.

       

  • Effective liquid handling

      From functional module perspective, in parallel with the instrument, the STRATEC LCM Pumps were developed allowing effective handling of trigger reagents and wash buffer. As the fluidics are pumped by membrane movement only, their chemical composition has no impact on module lifetime.

  • Connectivity

      While it was possible to connect the initial LIAISON instrument to a laboratory automation system (LAS) by a dedicated loop running through the sample area, on the LIAISON® XL this application was already considered during the development and a dedicated pipettor gantry now allows direct access to an LAS track next to the instrument. 

  • New Loading concept

      With previous benchtop systems, the canisters for system fluids had to be placed next to the instrument. A new concept developed by STRATEC made it possible to integrate the system fluids into the system – an advantage in terms of usability and footprint reduction.

  • Cuvette gripper

      A specifically developed cuvette gripper ensures reliable transportation of the cuvettes inside the instrument between the modules.

  • New reagent

      In collaboration with DiaSorin, a new reagent was introduced to ensure efficient cleaning of the steel needle without impacting the reliability of the instrument.

ADVANTAGES

LIAISON® XL
  • Highly flexible test request management
  • Intuitive, compact and fully accessible
  • High system performance
  • Easily integration  with automated sample processing lines
  • Extended walkaway times
  • Long-term accuracy
LIAISON® XS
  • Highly flexible test request management
  • Intuitive, compact and fully accessible
  • High system performance
  • Extended walkaway times
  • Long-term accuracy
  • Footprint reduction

STRATEC Competences

Involved Services

The development and manufacturing of the LIAISON® XL and LIAISON® XS involved key teams at STRATEC as follows:

Icon customer satisfaction
Project Management

Coordinated timelines and resources.

Application

Assay Integration, Feasibility Studies

Software

Development, UI Design, and Usability

Instrumentation icon
Instrument design

Cover development according to design requirements

Mechanical Engineering 

unique mechatronic design integrating  related engineering disciplines and manufacturing technologies like  Injection molding 

Instrumentation icon
System architecture

 

Electronic Engineering & Embedded Software 

Proprietary CAN technology with on-site firmware update mechanism